HPLC Method for Analysis of Pseudoephedrine and Fexofenadine from Allegra D Tablet on Primesep 100 Column

HPLC-Applikation • Datum: 2022/07/22
HPLC Method for Analysis of  Pseudoephedrine and Fexofenadine from Allegra D Tablet on Primesep 100  Column Chromatogramm

High Performance Liquid Chromatography (HPLC) Method for Analysis of Pseudoephedrine (PSE) , Fexofenadine hydrochloride .

Pseudoephedrine is one of the most popular decongestant drugs on the market, in part due to its efficacy and in part due to its status as an amphetamine. It has the chemical formula C10H15NO . It has been reported to have been misused as a psychostimulant, since it is accessible over-the-counter. It was a banned substance by the International Olympic Committee (IOC) until 2004, but was banned again in 2010.

Fexofenadine is a common antihistamine with the chemical formula C32H39NO4 . It is used to treat hives, itching, and hay fever. Pseudoephedrine and Fexofenadine can be separated, retained, and analyzed on a Primesep 100 mixed-mode column using an isocratic analytical method with a simple mobile phase of water, Acetonitrile (MeCN), and a sulfuric acid (H2SO4) buffer. This analysis method can be UV detected at 200 nm with high resolution and peak symmetry.

Methodenparameter

ColumnPrimesep 100, 4.6 x 150 mm, 5 µm, 100 Å, dual ended
Mobile PhaseMeCN – 65%
BufferH2SO4 – 0.2%
Flow Rate1.0 mL/min
DetectionUV 200 nm